Report Processor Error - The Data Area Passed To A System Call Is Too Small

Article ID

ias-5433

Article Name

Report Processor Error - The Data Area Passed To A System Call Is Too Small

Created Date

20th February 2008

Product

Problem

It has been identified that when trying to print from an IRIS module the following error can occur: REPORT PROCESSOR ERROR An Error Has Occurred - The Details Are As Follows: Module .rpw_DEVMODE.cpp Line Number 348 Win32 Error Code 122 Win32 error message: The data area passed to a system call is too small Description: Failed to get the count of paper sizes for printer

Resolution

Following the steps below may resolve the issue with printing.
  • Click Start
  • Click Control Panel
  • Click Printers and Faxes
  • Right-Click on the printer
  • Choose Properties
  • Click on printing preferences button.
  • Ensure Paper size is set to A4
  • Click OK
  • Click Advanced Tab
  • Untick the box labelled Enable Advanced Printing Features
  • Click OK and then Retry the Report

    Share This Page